Organ-based tube current modulation
Witryna3 lis 2024 · In case your scanner doesn’t provide the possibility of gantry tilting (e.g., Dual Source Scanner) it is recommendable to use organ-based tube current modulation (X-Care) or bismuth shields. Further it is desirable to have a low-dose protocol for patients undergoing examination for evaluation and follow-up of the size of cerebrospinal fluid ... Witryna381 Dixon et al.: Organ dose modulation in CT 381 Journal of Applied Clinical Medical Physics, Vol. 17, No. 3, 2016. A contemporary solution offered by some CT manufacturers is to reduce the dose to radio - sensitive anterior organs by reducing the tube current when the X-ray tube is in the anterior position.
Organ-based tube current modulation
Did you know?
Witryna14 wrz 2024 · Using ImPACT MC software, Monte Carlo simulations of OEMON and OEMOFF were run on 8 cases involving fetal CT scans. We confirmed that the organ-effective modulation X-ray output modulation angle was 160°; the X-ray output modulation rate increased with increasing tube current; and no modulation … Witryna12 lis 2015 · Objectives Organ-based tube current modulation aims to reduce exposure to radiosensitive organs like the breasts by considering their anatomical …
Witryna15 lip 2024 · The use of organ-based tube current modulation resulted in an approximately 30% decrease in lens dose. However, image noise increased as much as 30% in the posterior and central parts of the brain ... Witryna24 mar 2024 · A new organ-based tube current modulation (NOB-TCM) method was designed with the intent to decrease tube current by 30% over a prescribed 90° …
WitrynaPurpose: The purpose of this work was to evaluate dose performance and image quality in thoracic CT using three techniques to reduce dose to the breast: bismuth shielding, … Witryna1 gru 2024 · Request PDF On Dec 1, 2024, T. Kaasalainen and others published The impact of patient off-centring on organ-based tube current modulation in chest CT: a phantom study with MOSFET dosimeters ...
WitrynaObjectives: To investigate the effect of an organ-based tube current modulation (OTCM) technique on organ absorbed dose and assess image quality in pediatric CT …
WitrynaObjectives: Organ-based tube current modulation aims to reduce exposure to radiosensitive organs like the breasts by considering their anatomical location and altering tube current during rotation. Former phantom studies demonstrated a dose … ez link or singapore tourist passWitryna11 kwi 2024 · The mean effective doses were 13.44 ± 4.05 mSv and 6.07 ± 3.40 mSv, respectively, and the mean SSDEs were 13.84 ± 2.94 mGy and 5.69 ± 2.27 mGy, respectively. The high-spike CT protocol without ECG monitoring reduced the radiation exposure by 55% compared to the protocol with ECG monitoring (from 13.44 mSv to … does citi charge foreign transaction feesWitrynaObjective: The purpose of this study was to assess the difference in absorbed organ dose and image quality for MDCT neck protocols using automatic tube current … does citibank offer personal loansWitryna2 lis 2024 · This study aimed to determine organ doses based on Monte Carlo (MC) simulations for individual paediatric patients undergoing chest–abdomen–pelvis computed tomography (CT) examinations and to evaluate correlations of organ doses with dose metrics. ... in tube current modulation (TCM) for CT examinations, the … does citibank offer prepaid cardsWitrynaPurpose: Organ-based tube current modulation (OB-TCM) techniques, which are provided by three vendors, reduces the radiation dose to the lens of the eyes by … does citi bank sell foreign currencyWitryna15 lis 2011 · @article{osti_22098670, title = {Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current}, author = {Jia, Wang and Xinhui, Duan and Christner, Jodie A. and Shuai, Leng and Lifeng, Yu and McCollough, Cynthia H.}, … ez link thermoWitryna5 lip 2024 · Objectives To assess the impact of patient off-centering on organ dose and image noise for head and thoracoabdominal CT in a pediatric phantom. Methods An anthropomorphic phantom simulating a 5-year-old child was used. Semiconductor dosimeters were placed in various cranial and thoracoabdominal organs. Head and … does citi card offer extended warranty